Chison EBit10 is a black & white ultrasound with premium image quality. It is the same as ultrasound as the EBit 50 and 60 but without the color function. This is the best black and white ultrasound on the market today. High frequency probes 7.0 - 18.0MHz. This ultrasound is sold exclusively by KeeboMed.
General information
Dimensions and Weight of Main Unit
- Dimensions: 358mm(Length)×125mm(Width)×399mm (Height)
- Net Weight without probe: 7.8kg
- Power supply voltage: Autoadaptable for AC100-240V
- Power supply frequency: 50-60Hz
- Power consumption: 150VA
User interface Operation Panel
- Control panel
- Alphanumeric keyboard
- 8 STC Slides
- Interactive back lit keys
- High-resolution color LCD
- Diagonal dimension: 15 inch
- Resolution: 1024X768
- Brightness adjustment
- Integrated speaker
- Volume adjustable
System overview
- Applications
- Abdominal
- Small parts
- Peripheral
- Vascular
- Transvaginal
- Trans-rectal
- Musculoskeletal
- Pediatric
- Fetal
- OB
- GYN
- Urology
Transducer Types
- Convex Probe: C3-E
- Linear: L7-E, L12-E
- Trans-Rectal: L7R-E, L7V-E
- Micro-convex: MC3-E, MC6-E, MC5-E
Image Modes
- B Mode
- B/M Mode
- M Mode
- 2B Mode
- 4B Mode
- 2DSteer (optional)
- PW Mode
- Trapezoidal Mode
- Quad/dual display
- Duplex mode: B/M
Display Annotation
- Logo
- Hospital name
- Exam Date/Time
- Mechanical index
- Tissue thermal index
- Patient Name and Patient ID
- Gender
- Birthday, Age
- Sonographer
- LMPGAEDD
- System status (real-time or frozen)
- Cineguide
- Measurement summary window
- Measurement results window
- Probe type
- Frequency
- Menuindication
- Track-ball functions indication
- Imaging parameters
Standard Configuration
- High-resolution 15" LCD Display
- 2 Active probe ports
- Pulse Wave Doppler (PW)
- Power Doppler Flow Imaging
- ≥500G integrated hard disk
- USB ports: 4
- Ethernet port: 1
- S-video outport: 1
- VGA port: 1
- DVI port: 1
- Footswitch: 1
- Remote:1
- General measurement package
- Clinical measurement packages
- Multi-language screen display
- Review: images review system
- Archive: patient information management system
- Reporting system
- AIO(AutomaticImageOptimization)
- Intelligent Zoom
- Speckle Reduction Algorithm (SRA)
- Q-Imagesoftwarepackage
Software Options
- DICOM (storage, SR, print, worklist)
- ECG
- 2D Steer Hardware Option
- Convex transducer: C3-E
- Linear transducer: L7-E, L12-E
- Trans Rectal transducer: L7R-E, L7V-E
- Micro-convex transducer: MC3-E, MC6-E, MC5-E
- Footswitch
- Carrying case
- Trolley
- ECGcable
- Bag
Peripherals
- Video printers:
- SONY UP897MD, SONY UP-D711MD, SONY UP-X898MD
-
PC printers:
- EPSON L120 Series
- EPSON L130 Series
- EPSON L310 Series
- EPSON L380 Series
- EPSON L805 Series
- EPSON L1110 Series
- EPSON L1118 Series
- HP DeskJet 1010 series
- HP OfficeJet Pro 6230
- HP LaserJet 1020 Plus
- HP LaserJet P2055d
- HP LaserJet Pro M12a
- HP LaserJet Pro P1102
- HP LaserJet Pro P1102w
- HP LaserJet Pro P1108
- HP LaserJet Pro 200 color M251n
- HP Color LaserJet Pro M252n
- HP Color LaserJet Pro M252dw
- HP Color LaserJet Pro M254nw
Imaging processing and presentation
-
B Mode
- Gain: 0~255, 256levels
- Framerate: MAX:1801(depends on probes)
- STC: 8 segments
- Depth:MAX:36.7cm(dependsontheprobes)
- Freq.:MIN:2MHz,MAX:H18MHz(dependsontheprobes)
- FHI:ON/OFF
- AIO:ON/OFF
- Invert:ON/OFF
- X-CONTRAST:Normal/Enhance/Suppress,3levels
- U/Dflip
- Zoom
- Fullscreen
- Focusnumber:1~8,8levels(dependsontheprobes)
- Compound:ON/OFF
- SRA:ON/OFF
- Density:High/Low
- Dynamic:30~165,16levels
- Focus position: 1cm~16cm, 16 levels
- Q-Image:0~3,4levels
- Persistence:0~7,8levels
- B Rejection:0~256,257levels
- Scan width:14%~100%,16levels
- Gamma:0~8,9levels
- Smooth:0~7,8levels
- Edge enhance:0~6,7levels
- Acoustic power:0~100%,101levels
- L/R Flip:ON/OFF
- Rotation:0~270,4levels
- Chroma:0~28,29levels
- 2D Map:default,1~20,21levels
- Screen brightness:20~100,17levels
- Zoom coef:60%~100%,8levels
- Trapezoidal imaging (only for linear transducer):ON/OFF
- 2D steer (only for linear transducer):-20~20,41levels
- ECG:ON/OFF
- Biospy:ON/OFF
- Needle Angle (only for linear transducer):-30~30
- Center Line:ON/OFF
- LGC: ON/OFF
- Keyboard light:ON/OFF
- Light intensity:1~16,16levels
-
M Mode
- Dynamic:30~165,16levels
- M Chroma:0~8,9levels
- Speed:1~4,4levels
- Layout:LR/UD,2levels
- M2D map:default,1~20,21levels
-
PW Mode
- Gain:0~255,256levels
- Freq.:MIN:2MHz,MAX:15MHz (depends on the probes)
- Wall Filter: 0~3, 4 levels
- Triplex mode
- Steer:-20~20,5levels
- Invert:ON/OFF
- PW chroma: 0~28, 29 levels
- Audio:0~100%,101levels
- PRF: MIN: 250Hz, MAX: 20kHz
- Speed:0~2,3levels
- Baseline:0~6,7levels
- Angle:0~70,8levels
- SV:0.5~20mm,8levels
- D2Dmap:default,1~20,21levels
- SpectrumEnhance:0~3,4levels
- DynamicRange:46~67,8levels
-
Cineloop
- Support 2D,M,PW
- Cine-loop auto/manual
- Variable cine play back speed
- User-define start and end frame of cine storage
- User-define start and end frame of cine review
- storage in hard disk and display in real-time modes
- Slideshow: slideshow function
- Storage ≥500GB integrated hard-drive
- USBdriver
- Still images storage format: BMP
- Still images export format: BMP,JPG,DCM
- Cineloops storage format: CINE
- Cineloops export format: AVI
- Review Image review Layout: 1×1,2×2,4×4
Image management
- Archive
- Patient Info
- Review Report
- Backup exam
- Restore exam
- Send exam
- Delete exam
- Patient view
- Study view
- Expand all
- Collapse all
- Select all
- New Exam
- Continue Exam
- Edit Exam
- Review
Measurement & calculation
- General Measurement Package
- Software packages for various specific clinical use
- Comprehensive analysis methods
- Clinical analysis reports
General measurement package
- General B mode measurement
- Distance
- Circumference/area
- Volume(3Distances)
- Volume(2Distances)
- Volume(1 Distance)
- Volume(1 Ellipse)
- Volume(1Ellipse1Dis)
- Ratio(distance/ area)
- Angle
- Strain Ratio
- Histogram
- profile
- M mode measurement
- Distance
- Time
- Velocity
- Heart Rate
- General PW mode measurement
- Velocity
- Distance
- Peak
- Trace
- StD%
- StA%
- ICA/CCA
- Volume Flow
- Heart Rate
Clinical Analysis Packages
- Canine
- Feline
- Equine
- Bovine
- Ovine
- Cardiology
Probe Parameter
- Convex transducer:
- C3-E, 3.5MHz, 2.0-6.8MHz
- Linear transducer:
- L7-E, 7.5MHz, 4.0-15.0MHz
- L12-E, 12.0MHz, 7.0-15.0MHz
- L7R-V, 7.5MHz, 4.0-15.0MHz
- L7W-E, 7.5MHz, 4.0-15.0MHz
- Micro-convex transducer:
- MC3-E, 3.0MHz, 2.0-6.8MHz
- MC5-E, 5.0MHz, 4.0-10.7MHz
- MC6-E, 6.0MHz, 4.0-12.0MHz
System setup
By using system Setup, users could
- Customize hospital information
- Customize Patient
- Customize Date and time
- Customize language
- Customize Screen Controller
- Customize Trackball Option
- Customize Auto Export
- Customize screen type
- Customize Cine Frames
- Customize Print De-Identification
- Option for Image Area
- Option for Transmitted Images
- PC Print Image Option
- Customize hotkey functions
- Function Config
- Customize Unit
- Customize Measure Option
- Customize Measure Result
- Customize Follicle
- Customize Heart Rate
- Customize AutoTrace
- OB Table
- Customize measurement package
- Customize comment
- Customize bodymark
- Customize exam mode
- Customize Image Freeze Config
- Customize Report
- DICOM setting
- Net setting
- Customize Storage
- Customize Net Printwe
- System information
- function setting
- hardware function
- Installment
- Video&VGA setting
- System Maintainance
User Define Functions
By user-define function, users could customize user-define preset, including:
- Applications name,
- Presets name,
- User defined name
- Applications exam type
- Imaging parameters
Multi-language Display Interface
- English
- Chinese
- Other languages
- Note: other languages for detailed, please contact us.
Inputs & outputs
- System power in: 1
- Ethernet: 1
- S-video: 1
- Footswitch port: 1
- USB port: 4
- Video out: 1
- Remote control: 1 VGA: 1
- DVI: 1
- ECG port: 1
- Ambient temperature: 10°C to 40°C
- Relative humidity: 30% to 75%
- atmospheric pressure: 700 hPa to 1060 hPa
- Ambient temperature: -5°C to 40°C
- Relative humidity: ≤80%
- Atmospheric pressure: 700 hPa to 1060 hPa