On Sale

BLT M7000Vet Biolight Veterinary Monitor

Sale price

Regular price $1,599.00
( / )

M7000Vet BLT Biolight Veterinary Patient Monitor.  FDA approval.  Used in hospitalsand clinics for monitoring patients: ECG, Respiration-breathing, NIBP, SPO2, Temperature Heart rate.  BLT M7000Vet offers animal-specific software: canine, feline, equine, bovine.  Recommended for domestic feline and canine, for example, heart rate monitoring even detects heart murmurs in cat.

Product Features

  • 7" TFT LCD display - high resolution
  • Built-in rechargeable battery
  • User-Friendly operational window
  • 60s full disclosure of ECG playback
  • 48 hours tabular and graphic trends & data storage
  • Digital SPO2, high capacity against interference of ESU, motion & low infusion
  • Isolated against defibrillation effect
  • Wireless or wire communicable with central station system
  • Parameter : 5 Lead ECG, RESP, Digital SPO2, NIBP, TEMP

Technical specifications

  • Safety: IEC60601 (GB9706)
  • Dimension: 256mm (W) x 209mm (H) x 185mm(D)
  • Weight: 4 Kgs (with battery)
  • Power Supply : 100~240V; AC: 47~ 63 Hz 12 VDC
  • Alarm Indication: Visual and audible alarm

ECG 

  • Has Leads: I, II, III, aVR, aVL, aVF, Cx
  • M7000 has Gains: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, auto
  • Accuracy: ±1BPM
NIBP 
  • Method: Automatic oscillometric
  • Operation Modes: Singles (manual), Cycle (automatic), Rapid (continuous)
  • Measurement : Systolic pressure/diastolic pressure/mean
  • Range: Adult: 10-270mmHg
  • Pediatric: 10-235mmHg
  • Neonate: 10-135mmHg
  • Unit: mmHg / Kpa selectable
  • Auto Measurement: 1, 2, 3, 4, 5, 10, 15, 20, 30, 45, 60, 90 minutes, 2, 4, 8, 12 hours
  • 600 groups of NIBP measuring data review

RESP

  • Method: Impedance Measurement
  • Measuring Range: 0-120bpm
  • Alarm Limit: 0-120bpm, upper and lower limit continuously adjustable
  • Apnea alarm: Available
  • BLT Digital SPO2 (Pulse Oximetry)
  • Range: 0-100%
  • Accuracy: ±2% (70%~100%); ±3%(35%~ 69%) Unspecified (0~34%)
  • Range & Accuracy of Pulse Rate : 25~250BPM ±1BPM

TEMP

  • Channel : 2 channels
  • Range : 0~50°
  • Unit : Celsius, Fahrenheit
  • Resolution : 1mmHg
  • Accuracy : ±0.1°(25°~50°)
  • Humidity - Operation: 10%~95%, non condensing
  • Storage / Transportation : 0%~93% non condensing
  • Atmospheric Pressure: Operation: 700~1060hPa
  • Storage / Transportation : 500~1060hPa
  • Standard configuration: ECG , Heart Rate, RESP, NIBP, SPO2, RR, Temperature, Battery
  • Option: 2-TEMP, Thermal Recorder, Nellcor SPO2

Customer Reviews

No reviews yet
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)