BLT M9000Vet Biolight Veterinary Monitor

$1999.00 Sale

BLT M9000Vet Biolight Patient Vet Monitor.  M9000 has FDA approval for monitoring of vital signs functions. Recommended for use in hospitals and clinics for: ECG, Respiration-breathing also NIBP-non invasive blood pressure, Pulse rate, SPO2, Temperature, (optional IBP and Multi-gas/O2) parameters.   Features of the monitor are listed below:

Standard Configuration includes : SpO2,NIBP,PR,HR,T and ECG.

  • 12.1" LCD display- high resolution
  • Digital SPO2 technology offers anti-motion and anti-low perfusion functions
  • 168 hours storage
  • Bed to bed view
  • Product Specification/Models
  • Safety: IEC60601 (GB9706)
  • Dimension: 318mm (W) x 264mm (H) x 152mm(D)
  • Power Supply : 100~240V; AC: 50~ 60 Hz
  • Alarm Indication: Visual and audible alarm
  • 1800 groups of alarm events review
  • Application: Adult, Pediatric and neonate
ECG 
  • Leads: I, II, III, aVR, aVL, aVF, V
  • Gains: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, auto
  • Input impedance: = 5MO (d.c.~60Hz)
  • Common Mode Rejection Ratio: = 85dB (diagnostic mode) = 105dB (monitoring & surgical mode)
  • Bandwith: 0.5-40Hz (monitoring mode) 0.05-120Hz (diagnostic mode) 1-25Hz (surgical mode)
  • Protection: Segregation breakdown voltage 4000VAC, 50/60Hz Resistant to high-frequency electrotome, myoelectricity, AC, drifting interference
  • Indication of Detachment of electrodes: Available
  • Playback of Cardiogram: Available
  • Scanning Speed: 12.5mm/s, 25mm/s, 50mm/s
  • Heart Rate Range: 10-300BPM
  • Accuracy: ±1BPM
  • ECG waveform playback: 30 minutes
NIBP 
  • Method: Automatic oscillometric
  • Operation Modes: Singles (manual), Cycle (automatic), Rapid (continuous)
  • Measurement: Systolic pressure/diastolic pressure/mean pressure
  • Range: Adult: 10-270mmHg
  • Pediatric: 10-235mmHg,
  • Neonate: 10-135mmHg
  • Unit: mmHg / Kpa selectable
  • Auto Measurement: 1, 2, 3, 4, 5, 10, 15, 20, 30, 45, 60, 90 minutes, 2, 4, 8, hours
  • 1000 groups of NIBP measuring data review
RESP 
  • Method: Impedance Measurement
  • Measuring Range: 0-120bpm
  • Alarm Limit: 0-120bpm, upper and lower limit continuously adjustable
  • Apnea alarm: Available
  • BLT Digital SPO2 (Pulse Oximetry)
  • Range: 0-100%
  • Accuracy: ±2% (70%~100%);
  • ±3%(35%~ 69%)
  • Unspecified (0~34%)
  • Range & Accuracy of Pulse Rate: 20~250BPM ±1BPM
TEMP 
  • Channel: 2 channels
  • Range: 0~50°
  • Unit: Celsius, Fahrenheit
  • Resolution: 0.1°
  • Accuracy: ±0.1? (25°~50°)
  • Alarm Range: 0~50°
IBP 
  • Channel: 2 channels
  • Range: -50~300 mmHg
  • Resolution: 1 mmHg
  • Accuracy: ±2 mmHg (±2%) without probe ±4 mmHg (±2%) with probe
  • Unit: mmHg, Kpa
  • Converter sensitivity: 5 uV/V/mmHg
  • Names of pressures: ART/PA/CVP/LAP/RAP/ICP
EtCO2 (side stream) 
  • Method: Infrared spectrum
  • Range: 0.0-13.1%
  • Resolution: 1 mmHg (0.1%)
  • Accuracy: 5% EtCO2